CA 19-9 | ||
---|---|---|
|
||
MiChart Code: CA 19-9 (Carbohydrate Antigen 19-9)
|
||
Soft Order Code: CA199
|
||
Synonyms:
|
||
Container: SST tube
|
||
Normal Volume: 0.5 mL serum
|
||
Minimum Volume: 0.25 mL serum
|
||
Offsite Collection: Collect blood in a red top or SST tube. Centrifuge, aliquot serum into plastic vial and refrigerate.
|
||
Onsite Collection (Michigan Medicine Hospitals Only): Collect blood in a red top or SST tube.
|
||
Days Set Up: Daily, 24 hours
|
||
Analytic Time: 4 hours
|
||
Reference Range: *Reference ranges may change over time. Please refer to the original patient report when evaluating results.
<40 U/mL. Serum markers are not specific for malignancy, and values may vary by method.
|
||
Test Usage: Potentially useful adjunct for diagnosis and monitoring pancreatic cancer; Maybe used for differentiating patients with cholangiocarcinoma and primary sclerosing cholangitis (PSC) from those with PSC alone.
|
||
Test Methodology: Chemiluminescent Immunoassay
|
||
Additional Information: Tested by a chemiluminescent immunoassay manufactured by Siemens Healthineers, performed on Atellica IM system. Results determined from different manufacturers and/or methods may not be comparable.
|
||
LOINC: 2009-9
CPT Code:86301
Fee Code:32042
Alternate Specimen:Red Top Tube
Specimen Retention:4 days
|
||
Test ID: 235
|